Predictive light calculation
There are many light calculation programmes within the lighting field.
All providing forms of relative outcomes.
It was with a large scale project for the Department of Justice of the Government of Victoria, the full workings of AGi32 became the chosen tool of trade. Undertaking extensive works within the virtual world. It was during the site inspection, using a high performance calibrated light meter, revealed the variant between calculated outcome and the actual to which there was a mere 0.2 of a lux differential.
This is well below the perceived capability of the human eye.
This is well below the perceived capability of the human eye.
Requirements of AGi32 - imports 2D or 3D files created in CAD programs that are in DWG or DXF format.
** Sometimes the original CAD (DWG) file cannot be found but there is a pdf. **
There is a solution!
Lux Plot Design can convert a .pdf of the required works to be designed and produce a CAD (DWG) outcome.
** Sometimes the original CAD (DWG) file cannot be found but there is a pdf. **
There is a solution!
Lux Plot Design can convert a .pdf of the required works to be designed and produce a CAD (DWG) outcome.
Goniophotometer
An instrument for measuring a property of light,
especially luminous intensity or flux.
The NATA accredited photometric outcome is paramount.
Can your supplier provide the true performance of the fixtures?
Not just a mere suggestion!
And do all the fixtures have EMC compliance?
especially luminous intensity or flux.
The NATA accredited photometric outcome is paramount.
Can your supplier provide the true performance of the fixtures?
Not just a mere suggestion!
And do all the fixtures have EMC compliance?
The use of the black Body Radiator
Within the not so distant past, Fluorescent and Metal Halide lighting
dominated the commercial and industrial sector.
Now we add the new, not as yet commonly understood, LED, OLED and so on....
In short, the correct colour temperature required should be stipulated within the Brief,
but more importantly within the documentation for tender or purchasing.
This is where understanding the profile of the Black Body Radiator comes in to true
lighting design.
Within the not so distant past, Fluorescent and Metal Halide lighting
dominated the commercial and industrial sector.
Now we add the new, not as yet commonly understood, LED, OLED and so on....
In short, the correct colour temperature required should be stipulated within the Brief,
but more importantly within the documentation for tender or purchasing.
This is where understanding the profile of the Black Body Radiator comes in to true
lighting design.
AGi32 at work
Fluorescent High Bay - Alternative
Food Processing
Heavy Industrial & Mining
Infrastructure
Train Station (7M wide 3M Set back)
Train Station Platform Lighting based on a Metro
Line - Lighting Levels (Render)
Train Station Platform Lighting based on a Metro
Line - Lighting Levels (Render)
Statistical Analysis
Burial Hill (now part of the Flagstaff Gardens)
was the first burial place for white settlers in Melbourne
This Statistical Analysis snapshot depicted is of Park lighting only.
To compare what is in situ and an alternative.
Purely changing the post top to a Dark Sky - Acorn Glass Fixture.
Sports Lighting - Indicative positions and levels
Dressage Arena
Olympic standard - Dressage arena lighting
Lighting Levels for indoor Arena for Competition (Render)
Lighting Levels for indoor Arena for Competition (Render)
Melbourne Cricket Ground – Aiming schedule for the 6 External Towers
The 6 External Towers with highest mounting height set at 84 Meters
Using a quantity of 104 x Philips 2Kw - 09903 for each Tower.
This design and aiming array is based on both "Front of House lighting for Ballet " and "Theatre in the Round" Lighting focus formats
Using a quantity of 104 x Philips 2Kw - 09903 for each Tower.
This design and aiming array is based on both "Front of House lighting for Ballet " and "Theatre in the Round" Lighting focus formats
AFL sports ground Scaled through Google Earth into AGi32 to produce a CAD for construction
We can stitch up to 8 Google earth images to create 1 scaled image to draw to and place the poles and Light fittings to show conformity to required standards
Aviation Lighting - Manual of Standards Part 139
VISUAL AIDS PROVIDED BY AERODROME LIGHTING
Apron Floodlighting
Lighting in the Vicinity of an Aerodrome
Apron Floodlighting
Lighting in the Vicinity of an Aerodrome
LED Street Signage
Proposed Signage for local Council Approval
A report comparison is supplied
Google Earth scales the location
An outcome in DWG OR pdf format is supplied
A report comparison is supplied
Google Earth scales the location