Lux Level Testing Service
On Site - Lighting level verification and Commissioning.
All testing is performed with calibrated and certified High Performance testing Equipment for both
Meter readings in Lux - The SI unit of illuminance and luminous emittance, measuring luminous flux per unit area
Meter readings in cd/m2 - The SI unit for luminance is candela per square metre (cd/m2)
Reports are compiled and intended to be integrated into the project maintenance manual.
On Site - Lighting level verification and Commissioning.
All testing is performed with calibrated and certified High Performance testing Equipment for both
Meter readings in Lux - The SI unit of illuminance and luminous emittance, measuring luminous flux per unit area
Meter readings in cd/m2 - The SI unit for luminance is candela per square metre (cd/m2)
Reports are compiled and intended to be integrated into the project maintenance manual.
Build Form Development
Translating the lighting component of built form development, to meet both asset requirements and legislative requirements. This is achieved by the facilitation of lighting Lux outcome and giving accurate lighting fixture placement.
Lighting Design for the Design and Construct sector
The strong accruement of lighting knowledge attained are used within the lighting design process.
This is used to identify and specify lighting product suitable for the task at sustainable cost.
The emphasis on lighting design through cost analysis.
Linking the initial expenditure through to the life cycle of project
being a key role within the design processes.
Providing a cost evaluation of lighting and lighting products to improve productivity,
safety and where possible beautification.
Working directly with Architects, Designers and Contractors on design and construct projects.
Larger Projects
Our service, is to quantify the lighting outcome through light calculation.
Using AGi32, along with the brief given, to substantiate recommended lighting levels
required in the AS standards.
Representing the calculated outcome to show
- Quantity (Number of fixtures required) and the
- Quality (Amount of lamp Flux along with colour rendition on the working plane) of lighting
required will meet the Australian Standards
Australian Standards
• AS3827-Lighting System Performance • AS1680-Interior • AS1158-Road&Exterior • AS2293-Emergency • AS2560-Sports • AS4282-Control of Obstructive Light • BCA-Building Code of Australia • GBCA-Green Building Council of Australia (Green Star) • Aviation Lighting - Manual of Standards Part 139 |
Working Processes
• Working knowledge of lighting theory • Product knowledge • Photometrics • Industry practice standards • AGi32 Photometric toolbox and CAD • High Performance Calibrated test Equipment • Our Background in the lighting/electrical industry • Members of the IES(ANZ) • High uncompromising focus on customer service |